Plumbing services
Backflow Testing, Repair and Installation
Backflow testing is a check, usually required once a year, that confirms a backflow prevention assembly is working so dirty water cannot flow backward into the public drinking water supply. Utilities commonly require it for irrigation systems, fire sprinkler lines and commercial buildings, and a certified tester must do it.
Rules come from state drinking water programs and local water utilities, so requirements, deadlines and approved devices vary by location. If you received a notice from your water provider, keep it handy when you call.
Signs you need backflow testing
- You received an annual backflow test notice from your water utility
- You have an in-ground lawn sprinkler system
- Your building has a fire sprinkler system
- You run a restaurant, medical office, car wash or other commercial site
- A backflow device is leaking or dripping from the relief valve
- You are installing a new irrigation system, boiler or pool fill line
- Your device was damaged by a freeze
- Discolored water or low pressure after nearby water main work
What is backflow and why does it matter?
Backflow is the unwanted reverse flow of water, or other substances, into the drinking water system. It happens in two main ways:
- Back-siphonage: pressure in the public water main drops, for example during a main break or heavy firefighting, and water is pulled backward from a home or business.
- Backpressure: pressure on the customer side becomes higher than the supply, for example from a pump, boiler or elevated tank, and pushes water back into the main.
A cross-connection is any link between drinking water and a possible source of contamination. A sprinkler system can pull in fertilizer, pesticides and lawn water. A boiler can push treated water back. A hose left in a bucket of chemicals is a simple example. The EPA's Cross-Connection Control Manual describes backflow as a real public health risk, and it is why water utilities run cross-connection control programs.
Who is required to have backflow testing?
Requirements are set by state rules and local water utilities, and they vary. In general, testable assemblies and annual testing are commonly required for:
- Residential and commercial lawn irrigation systems
- Fire sprinkler and standpipe systems
- Commercial and industrial properties such as restaurants, medical and dental offices, labs, car washes, laundries and manufacturing
- Buildings with boilers, chillers or cooling towers
- Properties with a private well or auxiliary water supply in addition to city water
- Swimming pool fill lines and some multi-unit buildings
The water utility usually sends a notice with a due date. Missing it can lead to warnings and, in many areas, water service being suspended until the test is done. Check your notice or your utility's website for local rules.
What are the types of backflow preventers?
| Device | Protection level | Typical uses | Testable |
|---|---|---|---|
| Reduced pressure zone assembly (RP or RPZ) | High hazard | Commercial, medical, chemical injection, some irrigation | Yes |
| Double check valve assembly (DCVA) | Low hazard | Fire sprinkler systems, some irrigation | Yes |
| Pressure vacuum breaker (PVB) | Back-siphonage only | Residential irrigation | Yes |
| Spill-resistant vacuum breaker (SVB) | Back-siphonage only | Irrigation, indoor locations | Yes |
| Atmospheric vacuum breaker (AVB) | Back-siphonage only | Individual irrigation zones, some fixtures | No |
| Hose bib vacuum breaker | Back-siphonage only | Outdoor faucets | No |
| Air gap | High hazard | Sinks, tanks, softener and RO drains | Inspected, not tested with a gauge |
The local water authority decides which device is acceptable for each situation. Many utilities only accept assemblies approved by an organization such as the USC Foundation for Cross-Connection Control and Hydraulic Research or ASSE.
How does a backflow test work?
A certified tester uses a calibrated differential pressure gauge connected to the test cocks on the assembly. A typical test:
- The tester confirms the device model, size and serial number match the utility's records.
- Water downstream is briefly shut off. Expect a short interruption to irrigation or the building.
- Each check valve is tested to confirm it holds a minimum pressure difference and closes tightly.
- On an RPZ, the relief valve is tested to confirm it opens at the correct point.
- On a PVB, the air inlet and check valve are tested.
- The tester records the results, restores water and submits the test report to the water utility, often through an online portal.
Most residential tests are quick. A failed test usually means cleaning or replacing internal parts, then retesting.
What happens if my backflow device fails?
Common causes of failure include debris on the check valve seats, worn rubber parts, a stuck relief valve and freeze damage. Most assemblies can be repaired with a rebuild kit. If the device is damaged, very old, or no longer approved locally, it is replaced. After a repair, the assembly must pass a new test, and the results go to the water provider.
An RPZ that discharges water from its relief port is signaling a problem, often debris or a pressure fluctuation. Do not plug the relief port. It is a safety feature.
Do I need a certified tester?
Yes. Water utilities generally require that tests be performed by a tester certified under the state or local program, and many require the tester to be registered with that specific utility. Certification commonly comes from a state agency or from training programs such as ABPA or ASSE, with periodic recertification and gauge calibration. Ask the plumber for their tester certification number and confirm they are registered with your water provider before the test.
How do I protect a backflow device in winter?
- Irrigation backflow preventers above ground are easily damaged by freezing.
- Before the first freeze, shut off water to the irrigation system and drain the device following the maker's instructions, or have the irrigation system winterized.
- Insulated covers and enclosures help but do not replace draining in cold climates.
- In spring, open valves slowly. Many utilities expect a test after reinstallation or repair.
See also our guide on how to prevent frozen pipes.
Installing a new backflow preventer
New irrigation systems, boilers, fire lines and many commercial fixtures need a backflow preventer before they are connected. Installation typically requires a plumbing permit, the right device for the hazard, correct height and clearance above grade, a drain path for RPZ discharge, and an initial test report sent to the utility. A local plumber familiar with your water provider's rules can handle the process. See water pipes and plumbing services.
How it works
- Call (855) 902-0055Tell us what is going on and your address. We answer 24/7.
- A local plumber comes outA plumber serving your area arrives, finds the problem and explains it.
- Fixed rightYou get the price before work starts, then the job is done and cleaned up.
Backflow Testing: common questions
How often is backflow testing required?
Most water utilities require testable assemblies to be tested at least once a year, plus after installation, repair or relocation. High-hazard sites may be required to test more often. Your utility notice will list the due date.
Can I test my own backflow preventer?
Generally no. Utilities require a certified tester with a calibrated gauge, and the report must come from that tester.
Is the homeowner or the utility responsible for the device?
In most programs, the property owner owns and maintains the backflow assembly and pays for testing and repairs. The utility enforces the testing requirement.
Why is water dripping from my backflow preventer?
On an RPZ, water from the relief valve often means debris or a worn part is keeping a check valve from sealing, or there was a pressure swing. Have it inspected and repaired.
What happens if I miss the deadline?
Utilities usually send reminders first. Many can suspend water service to the property or the irrigation line until a passing test is filed. Rules vary by utility.
Related
Backflow Testing near you
- Plumber in New York, NY
- Plumber in Los Angeles, CA
- Plumber in Chicago, IL
- Plumber in Brooklyn, NY
- Plumber in Houston, TX
- Plumber in Phoenix, AZ
- Plumber in Philadelphia, PA
- Plumber in San Antonio, TX
- Plumber in Bronx, NY
- Plumber in San Diego, CA
- Plumber in Dallas, TX
- Plumber in San Jose, CA
- Plumber in Austin, TX
- Plumber in Jacksonville, FL
- Plumber in Fort Worth, TX
- Plumber in Columbus, OH
- Plumber in Saint Louis, MO
- Plumber in Charlotte, NC
- Plumber in Indianapolis, IN
- Plumber in San Francisco, CA
- Plumber in Saint Paul, MN
- Plumber in Seattle, WA
- Plumber in Denver, CO
- Plumber in Oklahoma City, OK
Need a plumber?
Drains, leaks, water heaters, sewer lines and emergencies, day or night.
Call (855) 902-0055